Certifications and Compliances
                                
                                
                                    ETL Listed to UL and CSA Standards: Hazardous (Classified) Locations
                                
                             
                            
                                
                                    ETL
                                
                                
                                    Class I, Division 2, Groups A, B, C, D; Temperature Code T4 (+135 °C) -P option only
                                
                             
                            
                                
                                    Enclosures
                                
                                
                                    NEMA 4, 4X and 12
                                
                             
                            
                                
                                    Heat Trace Load
                                
                                
                                    24 Amps @ 277 Vac (-R2 option); 24 Amps @ 600 Vac (-C option)
                                
                             
                            
                                
                                    Ambient Temperature
                                
                                
                                    -20 °C to +40 °C (-4 °F to +104 °F)
                                
                             
                            
                                
                                    Display
                                
                                
                                    Color LED, CFL 75,000h. Operator interface Analog touch pad (1,024 x 1,024). Program by channel or global. Temperature in °F or °C
                                
                             
                            
                                
                                    Control Power Input
                                
                                
                                    120 or 240 Vac, single-phase
                                
                             
                            
                                
                                    Control Temperature
                                
                                
                                    Set point -328 to +1392 °F range, adjustable
                                
                             
                            
                                
                                    Alarms
                                
                                
                                    High and low temperature alarms are adjustable. Ground fault and trip alarms are 1-500ma, adjustable. Current high and low alarms are 1-30 Amps, adjustable
                                
                             
                            
                                
                                    Auto-Test Cycle
                                
                                
                                    1-720 hrs, adjustable
                                
                             
                            
                                
                                    Predictive Maintenance Log
                                
                                
                                    Predictive log trigger values are adjustable
                                
                             
                            
                                
                                    Sensor
                                
                                
                                    RTD, 100 ohm, platinum, 3-wire
                                
                             
                            
                                
                                    Alarm Contacts
                                
                                
                                    Common for all alarms. Separate alarm contact for ground fault only
                                
                             
                            
                                
                                    Communications
                                
                                
                                    Serial RS-485, Modbus™ RTU protocol (-EC option); Ethernet TCP/IP Modbus™ RTU protocol (-NC option)